| Condensing ProTankless GWH C 800 ES |
|
|
|
|
|
| |
| |
|
|
|
|
| |
GWH C 800 ES
|
| Power Input |
NG: 199,000 BTU/Hr LP: 199,000 BTU/Hr
|
Maximum Flow to Activate
|
0.65 gallons per minute (gpm) |
Flow Rates
|
40°F rise@ 9.2 gpm 45°F rise@ 8.0 gpm 55°F rise@ 6.4 gpm 65°F rise@ 5.5 gpm 77°F rise@ 4.6 gpm 90°F rise@ 3.9 gpm
|
Energy Factor
|
NG: .91 LP: .91
|
Thermal Efficiency
|
NG: 92% LP: 92%
|
| Dimensions |
H: 30½" W: 17.875" D: 11¼" |
| Weight |
74 lbs.
|
| Modulating Gas Valve |
Min Firing Rate: 19,900 BTU/Hr Max Firing Rate: 199,000 BTU/Hr
|
| Ignition |
Electronic
|
| Accessories |
Concentric Termination Kit
(#BHW60L46)
Outdoor Kit (#PTOK)
[See PDF manual] Wireless Remote (#TSTAT2)
[See PDF manual] Tankless Link Cascading Kit (#TLINK) Pipe Cover (#PTPCES) [SEE PDF Manual] |
| GWH C 800 ES Installation Specifications |
| Gas Connection |
¾" Male NPT |
| Water Connections |
¾" Male NPT |
| NG Gas Pressure |
Minimum: 4" WC Maximum: 14" WC |
| LP Gas Pressure |
Minimum: 9" WC Maximum: 14" WC |
Water Pressure
|
Minimum: 30 PSI (Well): 40 PSI Maximum: 150 PSI
|
Electrical Supply
|
120V - (plugs in)
|
Installation Clearance
|
Top: 12" Front: 1" Back: 0" Sides: 1" Floor: 12"
|
|
|
|
|
|
|
| |
|
| |
|
| |