| | GWH 715 ES
| | Power Input | NG: 199,000 BTU/Hr LP: 199,000 BTU/Hr
| Maximum Flow to Activate
| 0.65 gallons per minute (gpm) | Flow Rates
| 35°F rise@ 9.2 gpm 45°F rise@ 7.3 gpm 55°F rise@ 5.9 gpm 65°F rise@ 5.0 gpm 77°F rise@ 4.2 gpm 90°F rise@ 3.6 gpm
| Energy Factor*
| NG: .83 LP: .83
| Thermal Efficiency*
| NG: 83+% LP: 83+%
| | Dimensions | H: 30½" W: 17.875" D: 11¼" | | Weight | Electronic
| | Modulating Gas Valve | Min Firing Rate: 19,900 BTU/Hr Max Firing Rate: 199,000 BTU/Hr
| | Ignition | 67 lbs.
| | Accessories | Horizontal Vent Kit (#4TWHVK3S) Outdoor Kit (#PTOK) [See PDF Manual] Wireless Remote (#TSTAT2) [See PDF Manual] Tankless Link Cascading Kit (#TLINK) Pipe Cover (#PTPCES) [SEE PDF Manual]
| *This information reflects the most up to date third party testing results.
| GWH 715 ES Installation Specifications | Gas Connection (inches)
| ¾" Male NPT | | Water Connections | ¾" Male NPT | Inlet gas pressure under operation (with a high hot water flow rate)*
| Propane: 8: - 13" water column Natural Gas: 3.5" - 10.5" water column
| | Water Pressure | Minimum: 30 PSI (Well): 40 PSI Maximum: 150 PSI | | Electrical Supply | 120V - (plugs in) | | Installation Clearance | Top: 12" Front: 1" Back: 0" Sides: 1" Floor: 12" | * To measure gas pressure, see Measuring Gas Pressure in your manual, chapter 3.12, page 24.
|
|
|
|
|
|
|
| |
|
| |
|
| |