GWH 635 ESO Technical Support
635 ESO Technical Support
 
   
   Technical Specifications
 
Technical Specifications
Power Input NG: 35,000 - 175,000 Btu
LP: 31,000 - 175,000 Btu
Minimum Flow
Rate to Activate
.8 gallons per minute (gpm)
Flow Rates 90° F rise / 3.2 gpm
75° F rise / 3.9 gpm
65° F rise / 4.5 gpm
55° F rise / 5.2 gpm
45° F rise / 6.4 gpm
Energy Factor .80
Thermal Efficiency 87% (recovery efficiency)
Dimensions 23½”h x 15¾”w x 8½”d
Weight 47 lbs. (21 kg)
Ignition Electronic
Life Expectancy 20+ years
Optional Accessories Wireless Remote control
Installation Specifications
Gas Connection ¾" Male NPT
Water Connection ¾" Male NPT
LP Gas Pressure Minimum: 11" WC
Maximum: 14 " WC
NG Gas Pressure Minimum: 5" WC
Maximum: 14 " WC
Water Pressure Minimum: 30 PSI
Maximum: 150 PSI
Electrical Supply 120 VAC 50/60 Hz
Idle 40mA, Operation ≤ 2.5A
Warning: Do not mount heater directly onto vinyl siding.  A 6' x 4' area of vinyl siding must first be covered or replaced with wood or other non-plastic material.
   High Altitude Operation
Altitude Natural
Gas
Liquid
Propane
Special
Notes 
0 - 4,000 ft
(0-1,219 m)
no
modification
no
modification
For operation at elevations above 2,000 ft (610 m) the equipment ratings shall be reduced at the rate of 4% for each 1,000 ft (305 m) above sea level.
4,000 ft - 7,000 ft
(1,219m-2,134m)
CO2 adjustment with flue gas analyzer required
Refer to this tech bulletin.
Above 7,000 ft
(above 2,134 m)
Not approved
   
GWH 635 ESO
Bosch - GWH 635ESO
GWH 635 ESO Tech Support
 
Note: Specifications and product information subject to change without notice.