Bosch GWH 450 ESR
Bosch GWH 450 ESR
 
   
  GWH 450 ESR
Rated Efficiency
81%
Power Input 120,000 BTU/Hr
Maximum Output
98,400 BTU/Hr
Minimum Output
35,500 BTU/Hr
Water Temp in Heating Circuit*
115°F - 190°F
Maximum Exhaust Vent Length
39' with one elbow**
Dimensions H: 27½" W: 15¾" D: 11½"
Weight 47 lbs.
Modulating Gas Valve Yes

 *Temperature setting range     **(90° elbow equals 6'; 45° elbow equals 3')

Installation Specifications
Gas Connection ¾" Male NPT
Water Connections ½" Male NPT
NG Gas Pressure Minimum: 5.5" WC
Maximum: 8" WC
LP Gas Pressure Minimum: 11" WC
Maximum: 14" WC
Electrical Supply
120 VAC - plugs in
Exhaust Vent Size
3" AL 29-4C single wall sealed stainless steel vent pipe (Z-Flex, Protech, Heat Fab)
Intake Vent Size
3" Aluminum Flex, PVC or any other rigid or semi-rigid sealed pipe

   
Technical Support
 
Note: Specifications and product information subject to change without notice.