| Model |
RP27PT |
| Efficiency |
94% |
| Weight |
22 lbs. |
| Dimensions |
15¼" x 15½" x 4½" |
| Water Fittings |
¾" male NPT |
| |
| Electrical Requirements |
| Volts |
240 |
| Kilowatts |
26.85kWh |
| Amps |
US: 120 (3 x 40 amps)* CANADA: 120 (1 x 120 amps)** |
| Wire Size |
US: 8 gauge (6 conductors & ground) CANADA: 2 gauge (2 conductors & ground)** |
| Phase |
Single |
| |
| Minimum Flow Rate at Given Temperature Rise |
| 45ºF Rise |
4.0 gpm*** |
| 50ºF Rise |
3.7 gpm |
| 60ºF Rise |
3.0 gpm |
| 70ºF Rise |
2.6 gpm |
| 80ºF Rise |
2.2 gpm |
Average ground water temperature in the United States is 55ºF.
NOTE: The unit will not provide an output temperature above 131ºF.
* Minimum recommended service for the RP27PT is 200 amps
** In Canada unit must be wired to a single breaker. AE Canada Kit required and included. Always check local codes.
*** gpm = Gallons Per Minute †